    Brand Name : Atech sensor
    Model Number : PL315
    Certification : CE
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 10000 pcs month
    Delivery Time : 5-8 working days
    • Product Details
    • Company Profile

    CE Approved Water Level Data Logger PL315 Output Signal RS485 Digital

    Description

    Data logger PL315 is a high –performance and cost-efficient product developed by our company. By using of the best low consumption integrated chip and taking advantage of digital technology, PL315 is designed to record water depth (pressure) over long term. It could be widely used in petroleum. Chemi-industry, power station, water conservancy, city flood control and city water supply etc.

    PL315 is a battery powered instrument, and work without manual control. By setting proper interval recording time, one class AA battery 3.6/2400mAh is possible to support the PL315 working many years.

    PL315 works with an absolute pressure sensor. If the influence of air pressure fluctuations (e.g. at shallow fluid or water depths) is going to be taken into consideration, it is recommended that a second data logger PL315 is placed at the surface, to record the barometric pressure. The correct level is calculated via PC by subtracting the two measured values of the two data loggers.

    Sensor, circuit board and battery air assembled into the sealed steel housing, for submersible application. For data read out, PL315 must be got back from the measuring point. The O-ring sealed end cap is then removed to the access to data port.

    Specification

    Pressure range0-0.1~1.1MPa (Absolute)
    Environment Temp-30~80°c
    Overload pressure200%FS
    Error-10~+40°c 0.10%FS (typ.) 0.2%FS (max.)
    -30~+80°c 0.15%FS (typ.) 0.3%FS (max.)
    Stability<0.2%FS/year (typ.)
    Pressure Resolution0.01%FS
    Temperature Resolution0.1℃ (-30℃~80℃)
    Temp. Accuracy±1℃
    Recording interval1s~255 hours 59 minutes 59 seconds (1s~10 days 15 hours 59 minutes 59 seconds)
    Record data quantity50000 recordings (including data, time, temperature and pressure)
    Recording modeRecording stops when the records are 5000 recordings.
    Power supplyCylinder 3.6V/2400mAh Lithium battery (model:AA)
    Static Current≈20uA (no collection, no recording, no communication)
    Collection and Recording Current≈1.5mA
    Memory Eliminate Current≈30mA
    Output SignalRS485 digital
    Battery Life7 years (typ.) (1 measurement/hour)
    MaterialHousing: Stainless steel 316L (DIN1.4435)
    O-ring: Viton
    Weight≈500g
    ProtectionIP68
    Insulation100mΩ / 50V
    Vibration20g, 20 to 5000Hz
    Shock20g, 11ms
    Endurance1*10^7 pressure cycle, 0~100%FS, at temp.25℃

    Feature

    1. High measuring accuracy, resolution and robustness due to the

    use of the latest Micro-processing technique.

    2. High data security due to the use of a non-volatile memory.

    3. Powered by one 3.6V/2400mAh Lithium battery; 20uA standby

    current support long term collection.

    4. Easy opening and replacing the battery due to the multi-O-ring

    sealed construction.

    5. Completely record the pressure, temperature and the recording time.

    6. Flexibly set the collection interval time with the shortest interval time 1s,

    and the longest interval time 255 hours 59 minutes 59 seconds.

    7. 5000 recordings could be recorded.

    8. Read the pressure and the temperature value via RS485 communication

    interface at any time.

    9. Back to factory setup offers customer easy to restore factory setup

    when make incorrect operations and reduces the maintenance fees.

    10.High stable, hardware watch-dog and muti-track software inspection

    could reduce the system halted.

    11.High protection ,class IP68

    12.High accuracy class at wider temperature range -30~80℃.

    Dimension

    CE Approved Water Level Data Logger PL315 Output Signal RS485 Digital

    Electric Connection

    CE Approved Water Level Data Logger PL315 Output Signal RS485 Digital

    Pin 1RS485 A
    Pin 2RS485 B
    Pin 3GND (connects to internal circuit)
    Other pin is null

    Operating software

    CE Approved Water Level Data Logger PL315 Output Signal RS485 Digital

    CE Approved Water Level Data Logger PL315 Output Signal RS485 Digital


    Quality CE Approved Water Level Data Logger PL315 Output Signal RS485 Digital for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Atech sensor Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)